G.R.Y.N Generators

Voltage regulators

AVR-4

The AVR-4 is an electronic device that allows the alternator to produce a constant output voltage. The unit does not include moving parts; so it is able to operate in highly vibrating environments.

The AVR-5 is an electronic device that allows the alternator to produce a constant output voltage. The unit does not include moving parts; so it is able to operate in highly vibrating environments.

AVR-5

AVR-8

The sensor loss protection circuit disables the output when there is no voltage on the sensing input.Analog input is provided to allow external voltage adjustment.AVR has a fixture for a CT droop connection, to allow parallel running with other similarly equipped generators.

The AVR-12 is an electronic device that allows the producer to create a constant output voltage.
The device is equipped with an open-enclosure, resin-cast design and is designed to be installed in the Alternator Termination Box. The unit does not have moving parts; so it is able to operate in highly vibrating environments.

AVR-12

AVR-20

The AVR-20 is an electronic device that allows the manufacturer to produce a constant output voltage.
The device is equipped with an open-enclosure, resin-cast design and is designed to be installed in the Alternator Termination Box. The unit does not have moving parts; so it is able to operate in highly vibrating environments.

The AVR-40 is an electronic device that allows an alternator to produce a constant output voltage.Thanks to its high current output heat diffuser current, it is able to operate in very hot conditions and leads the alternatives that require high excitation currents.The sensing loss protection circuit disables the output when there is no voltage on the sensing input.An analog input ±3V is provided allowing external voltage adjustment. AVR has a facility for a CT droop connection, to allow parallel running with other similarly equipped generators. An overload protection circuit limits the output current to its rated value, preventing the device from malfunctioning under overload or short circuit.

AVR-40

AVR-8-380

AVR-8-380 is an electronic device that allows an alternator to produce a constant output voltage.
The unit measures the voltage of the voltage that varies from phase to phase connection and is able to drive alternators that require high excitation voltages.
The unit does not have a neutral connection and is ideally suited for marine use.
The sensing loss protection circuit disables the output when there is no voltage on the sensing input.
An analog input of ±3V is provided which allows for external voltage adjustment. The AVR has a fixture for a CT droop connection, to allow parallel running with other similarly equipped generators.
An overload protection circuit limits the output current to its rated value, preventing the device from malfunctioning under overload or short circuit.

Input and Detection Voltage
Voltage: Jumper choice 95-132V AC or 190-265V AC
Frequency: 50-60Hz
Exit
Voltage: 90V DC at 200V AC
Current: 4A DC, 8A DC to 15 seconds
Resistance: 15Ohms Minimum

Model 460

Model 440

Input and Detection Voltage
Voltage: Jumper choice 95-132V AC or 190-265V AC
Frequency: 50-60Hz
Exit
Voltage: 90V DC at 200V AC
Current: 4A DC, 8A DC to 15 seconds
Resistance: 15Ohms Minimum

Input and Detection Voltage
Voltage: 85-140V AC
Frequency: 50-60Hz
Exit
Voltage: 90V DC at 110V AC
Current: 10A DC, 15A DC to 15 sec

Model 230

Model 250

Input and Detection Voltage
Voltage: 85-140V AC
Frequency: 50-60Hz
Exit
Voltage: 90V DC at 110V AC
Current: 10A DC, 15A DC to 15 sec

Input voltage
Voltage: 35-150V AC
Frequency: 40-400Hz
Detection Stress
Voltage: 110-220-415V AC
Frequency: 50/60Hz
Exit
Voltage: 90V DC at 110V AC
Current: 10A DC, 15A DC to 15 sec

Model 448

Model 449

Input voltage
Voltage: 35-150V AC
Frequency: 40-400Hz
Detection Stress
Voltage: 110-220-415V AC
Frequency: 50/60Hz
Exit
Voltage: 90V DC at 110V AC
Current: 10A DC, 15A DC to 15 sec

Input voltage
Voltage: 35-150V AC
Frequency: 40-400Hz
Detection Stress
Voltage: 110-220-415V AC
Frequency: 50/60Hz
Exit
Voltage: 90V DC at 110V AC
Current: 10A DC, 15A DC to 15 sec

Model 438

Model 72GP

Input voltage
Voltage: 110-265V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 80-265V AC
Frequency: 50-60Hz
Exit
Voltage: 90V DC at 200V AC
Current: 6A DC, 8A DC to 15 seconds
Resistance 15Ohms Minimum

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 415V AC
Frequency: 50/60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC, 12A DC to 15 sec
Resistance 12Ohms Minimum

Model U6

Model D8, D12, D15, D20

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 415V AC in 2 phases, 220V AC in one phase
Frequency: 50/60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 8A DC 12A to 15 sec – Model D8
Current: 12A DC Forced 20A to 15 Seconds – Model D12
Current: 15A DC Forced 20A to 15 Seconds – Model D15
Current: 20A DC Forced 28A per 15 sec – D20 Model
Resistance 12Ohms Minimum

Input and Detection Voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 5A DC 8A to 15 sec – D5.1
Current: 12A DC 16A to 15 sec – D12.1
Current: 20A DC Forced 25A to 15 Seconds – Model D20.1
Resistance 15Ohms Minimum

Model D5.1, D12.1, D20.1

Model 101

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 415V in 2 phases, 200V in one phase
Frequency: 50/60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 15Ohms Minimum

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 415V in 2 phases, 200V in one phase
Frequency: 50/60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 15Ohms Minimum

Model T10

Model 11P

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Detection Stress
Voltage: 220V/110V
Frequency: 50/60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 15Ohms Minimum

Input and Detection Voltage
Voltage: 415V AC in 3 phases
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 15Ohms Minimum

Model 306

Model 1008

Input voltage
Voltage: 180-250V AC
Voltage Detection
Voltage: 415V AC in 2 phases/220V AC in 3 phases
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 8A DC forced 12A to 15 seconds
Resistance 12Ohms Minimum

Input voltage
Voltage: 180-250V AC
Voltage Detection
Voltage: 415V AC in 2 phases/220V AC in 3 phases
Frequency: 50-60Hz
Exit
Voltage: 180V DC at 220V AC
Current: 8A DC forced 12A to 15 seconds
Resistance 12Ohms Minimum

Model 1808

Model 2000

Input voltage
Voltage: 180-250V AC
Voltage Detection
Voltage: 415V in 2 phases/220V in one phase
Frequency: 50-60Hz
Exit
Voltage: 180V DC at 220V AC
Current: 8A DC forced 12A to 15 seconds
Resistance 12Ohms Minimum

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Voltage Detection
Voltage: 110-220-415V AC
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 12A to 15 seconds
Resistance 12Ohms Minimum

Reference: 3007PIN

Model 206 and 208

Input voltage and detection
Voltage: 415V
Frequency: 50-60Hz
Exit
Voltage: 200V DC at 220V AC
Current: 6A DC 10A to 15 sec – Model 206
Current: 8A DC 12A to 15 sec – Model 208
Resistance 12Ohms Minimum

Input voltage
Voltage: 220V AC
Frequency: 50-60Hz
Voltage Detection
Voltage: 110-220-415V
Frequency: 50-60Hz
Exit
Voltage: 200V DC at 220V AC
Current: 10A DC forced 15A to 15 seconds
Resistance 12Ohms Minimum

Reference: IG10BL

Model 63-7

Input voltage
Voltage: 180-250V AC
Frequency: 50-60Hz
Voltage Detection
Voltage: 220V AC
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 4A DC 8A for 15 seconds – Model 63-4
Current: 7A DC 12A for 15 seconds – Model 63-7
Resistance 12Ohms Minimum

Input voltage and detection
Voltage: 415V
Frequency: 50-60Hz
Exit
Voltage: 100V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 18Ohms Minimum

Model 43

Model 200

Input voltage and detection
Voltage: 415V
Frequency: 50-60Hz
Exit
Voltage: 200V DC at 220V AC
Current: 6A DC forced 10A to 15 seconds
Resistance 18Ohms Minimum

Input voltage and detection
Voltage: 415V
Frequency: 50-60Hz
Exit
Voltage: 265V DC
Current: 10A DC 18A to 15 sec – Model 2510
Current: 15A DC Forced 22A per 15 Seconds – Model 2515
Resistance 15Ohms Minimum

Model 2510 and 2515

Model 3810 and 3815

Input voltage and detection
Voltage: 415V in 2 phases
Frequency: 50-60Hz
Exit
Voltage: 380V DC
Current: 10A DC 18A to 15 sec – Model 3810
Current: 15A DC Forced 22A per 15 sec – Model 3815
Resistance 15Ohms Minimum

0